UPS
1500 VA, 2000 VA and 3000 VA

True On-Line Design

RS232 Communications
Input Power Factor Correction Site Wiring Fault indicator
Built-in Surge Protection Green Mode Operation
Microprocessor Control &  Communications Compatible with generators
Compact size, lightweight Optional internal SNMP/HTTP
Wide input voltage window Optional Extended Battery Time
High Efficiency Optional Frequency Conversion
Over crest ratio indicator  


PersonalSource Rugged COTS Rackmount 600 to 3000 VA Front View


PersonalSource Rugged COTS Rackmount 600 to 3000 VA Rear View

True On-line Design

A recent Bell Laboratories study indicates that blackouts account for less than 5% of power disturbances. The other 95% consist of surges, noise, sags and brownouts. Equipment connected to utility power experiences an average of 128 such events each month. These events can disrupt proper operation of sensitive computer based equipment, decreasing productivity and creates unnecessary production, service and data recovery costs.

A True On-line UPS is the only design that can provide the maximum protection against major power problems. This is accomplished through converting the incoming AC utility voltage to a DC voltage. From this DC voltage, an AC voltage is then completely regenerated by the UPS, providing a clean, well-regulated source to your equipment, thereby eliminating power related problems. This solidstate generator sets the True Regenerative On-Line UPS apart from all other Line-interactive and Off-line designs, which leave your sensitive equipment connected directly to the dirty utility power 99+% of the time. If your equipment is operating in a “Mission Critical” application, then you need a True On-line UPS and the PersonalSource is the best choice in True On-line UPS technology.

Input Power Factor Correction

All PersonalSource Series models include state of the art Input Power Factor Correction. This greatly reduces the amount of current demanded from your building wiring system, yielding an efficient,  “building friendly” UPS.

Microprocessor Control

The PersonalSource UPS incorporates advanced microprocessor technology. This technology makes possible a high level of internal UPS control as well as system information, data logging, self-diagnostics, SNMP and enhanced computer communication through any RS-232 port.

SNMP/HTTP Remote Management Support

An optional SNMP/HTTP Agent board is available for direct installation into all PersonalSource models. The SNMP/HTTP Agent provides for direct connection of the UPS to any 10Base2 or 10BaseT Ethernet LAN.  

Overall, the PersonalSource Series is uniquely qualified for critical systems combining advanced modular design features with highly reliable construction.

Technical Specifications:

PART NUMBER:

ETI0015
-2205

ETI0015
-2215

ETI0015
-2206

ETI0015
-2216

ETI0015
-2207

ETI0015
-2217

INPUT

Nominal Voltage:

120 VAC

230 VAC

120 VAC

230 VAC

120 VAC

230 VAC

Voltage Range:

87-140 V

170-255 V

87-140 V

170-255 V

87-140 V

170-255 V

Current (max):

11 A

5.9 A

14 A

7.6 A

21 A

11.6 A

Frequency:

50/60 Hz ±5%

Efficiency:

>86%

Power Factor:

>0.95

OUTPUT

VA Rating:

1500 VA

2000 VA

3000 VA

Power:

1050 W

1400 W

2100 W

Voltage
(selectable)

110 VAC

220 VAC

110 VAC

220 VAC

110 VAC

220 VAC

115 VAC

230 VAC

115 VAC

230 VAC

115 VAC

230 VAC

120 VAC

240 VAC

120 VAC

240 VAC

120 VAC

240 VAC

Frequency:

50/60 Hz (auto tracking)

Voltage Regulation:

±2%

Frequency Stability:

±0.3% (Battery mode)

Step Load Change:

±7% for 100% load variation

Harmonic Distortion:

Linear Load            <3%
Non-linear Load     <5%

Overload:

105% load for 50 seconds

Crest Ratio:

3:1

BATTERY3

DC Voltage:

72 VDC

96 VDC

Type:

Maintenance Free, Valve Regulated, Sealed Lead Acid, Flame Retardant, Absorbed Electrolyte

Backup time:

Full Load
Half Load

11 minutes typical
30 minutes typical

7 minutes typical
20 minutes typical

5.5 minutes typical
15 minutes typical

Recharge Time:

8 Hours to 90%

TRANSFER TIME

Line Fails/Recovers:

Zero time – true online, no transfer for brownout or blackout

UPS - Bypass/Reverse:

<4 ms for bypass transfers

After Overload:

Auto Transfer to UPS

Audible Noise

@ 1 Meter

<55 dBA

Indicators

LEDs

Line, Inverter, Battery Reserve, Load, Bypass, Alarm, Crest, Battery & Load Capacity Level

Audible Alarms

 

DC Mode, Low Battery, Over/Under Voltage, Over/Under Frequency, High Temperature, Over Load, Alarm.

Interface

Computer:

UPS industry style RS-232

Environment

Temperature:

0°C – 40°C (32°F – 104°F)

Humidity:

10% - 95% Non-condensing

Mechanical

Input Line Cord:
    120 VAC
   
230 VAC

6 Foot Cord with
NEMA 5-15P Plug

6 Foot Cord with
NEMA 5-20P Plug

6 Foot Cord with
NEMA L5-30P Plug

6 Foot Cord with
“Schuko” Style Plug

6 Foot Cord with
“Schuko” Plug

6 Foot Cord with
“Schuko” Plug

Output Receptacles:
  
 
120 VAC version
    230 VAC version

(6) NEMA 5-15R w/ cable restraints

(6) IEC320 w/ cable restraints

Weight:

xx lbs (xx kg)

xx lbs. (xx kg)

xx lbs. (xx kg)

Dimensions:  inches
H x D x W  (mm)

5.25 (3U) x 26.0 x 19.0
(133 x 660 x 483)

Approvals

Agency:

UL, CUL, FCC Class A  (CE on specified models only)

Information Request Form

Select the items that apply, and then let us know how to contact you.

Send product literature
Have an engineer contact me
Have a salesperson contact me
I prefer to be contacted by Email   Telephone  Fax  Regular mail
My requirement is immediate  1-3 months  3-6 months  Future

Name
Title
Company
Address
Email
Phone
Fax

To Better Help
You, Please
Describe Your
Requirements

ETI PowerStation UPS are the proven Standard!

Home Up

Send questions or comments about this web site to sales@ruggedsystems.com.
Copyright © 1991-2010 Energy Technologies, Inc. All Rights Reserved. Last modified: May 13, 2010

1st Energy™, 1st Power™, 911 Power™, AC24-7™, ACanytime™, ACanywhere™, ACbackup™, Airborne Power™, Airborne UPS™, Air Force Backup™, Air Force UPS™, Army Backup™, Army UPS™, Backup AC™, Backup Source™, Backup The Web™, Battle Power™, Blackout Prevention™, Business Back UPS™, clean UPS™, Coast Guard Power™, Coast Guard UPS™, Controlling Power™, DC24-7™, DC backup™, Disaster Recovery Power™, Eco Power Source™, eDocsPort™, Energy Tech™, ETI™, Extreme Power Source™, Global Power Source™, Global UPS™, Homeland Security 24-7™, Humanitarian Power™, Hybrid Energy Storage™, Hybrid Energy Technologies™, Improved Power™, Industrial Backup™, Intelligent PDU™,  Intelligent UPS™, Internet Power Manager™, Lab Power™, Lab UPS™, Light UPS™, Know Power™, Marine Corp Backup™, Marine Corp Power™, Marine UPS™, Medical AC™, Medical Backup™, Military Backup™, Navy Power™, Navy UPS™, Network Power Manager™, Office UPS™, open UPS™, Personal Power Source™, Petro Chem Power™, Pipeline Power™, Portable Power Plant™, Powering The Net™, Power Protection™, Power Security™, Preventing Blackouts™, Redundant Power™, Renewable Source™,  Rugged Power™, Rugged Systems™, SCADA power™, Security Gate Power™, Shipboard Power™, Shipboard UPS™, Signal Backup™, Solar Backup™, Solar Power Source™, Tactical Computers™, Tactical Field Office™, Tactical Office Systems™, Tactical Shelter Systems™, Telecom Power Source™, The Power Connection™, Traffic Backup™, Traffic Signal Backup™, UPStart™, Utility Backup™, wind UPS™, Warfighter Backup™, Warfighter Power™, and World Power™ are trademarks of Energy Technologies, Inc.

Diplomatic Power®, Expeditionary Power®, Extreme UPS®, Industrial Power Source®, Military Power®, Tactical Computer Workstation®, Tactical Data Vault®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, Tactical Micro Grid®, Tactical Power®, Tactical Power Plant®, Tactical Solar®, Tactical Solar Shelter®, Tactical Wind Turbine®  and Tactical UPS® are registered trademarks of Energy Technologies, Inc.

Legal Statements