The field proven Rugged Power™ UPS line is ideally suited for military, industrial, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in shipboard, airborne, vehicular, field deployed or fixed locations with controlled or uncontrolled environments. The "ETI0001-1027" was initially designed for Joint Operations HMMWV applications, becoming the standard for several programs. 

The heavy-duty chassis occupies only 3U (5.25") of rack space while delivering up to 1550 VA of clean, uninterruptible power PLUS an additional 1000 VA of conditioner power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The optional mounting kit includes flanges and legs for either horizontal or vertical positioning. 

The internal shielded input transformer provides galvanic isolation with provisions for both domestic (115 VAC, CONUS) and for international (220 VAC, OCONUS) input voltages. The input switches and the galvanic isolation transformers all provide a double pole isolated source for overseas locations where phase references and grounding are not consistent as well as for shipboard systems. 

The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front and rear panels with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. Various optional power distribution controls are available which mount on the front panel or remotely. 

The rear panel provides barrier terminal strips for the input and output power. Multiple input and output power panel options are available. A removable and washable intake air filter and high capacity stainless steel ball bearing fan provide added protection in both controlled and hostile environments. The air is drawn from the rear and exhaust air is diverted out the front vent, with alternate air flow directions optional. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials. For more information, see the Battery Technology section. The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to 60 hertz power. A frequency selection switch is available for those sites requiring 50 hertz output instead of the standard 60 hertz. The Status connector provides an  interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability.

See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series ETI0001-1402 for a version of this UPS with an integrated PDU and remote control.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction

Technical Specifications: 
P/N: ETI0001-1027

AC OUTPUT
Output voltage: UPS 120 VAC true sinewave standard, up to 600 VAC optional
Output rating: 
     UPS
     Power Conditioner
1550 VA 0.65-0.75 pf standard, optional to 24,000 VA
1000 VA standard, optional to 10,000 VA
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: 
     UPS
     Power Conditioner
± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)

Proportional to input
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: 
     UPS
     Power Conditioner
60 or 50 Hz ± 2.5% synchronized to utility
60 or 50 Hz ± 1.0% w/ utility not available
400 or 1000 Hz output available as an option
Same as input
Operational status Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
AC INPUT
Input voltage selection: Nominal 115 VAC or 220 VAC via terminal block
Input voltage tolerance: 
     UPS
     Power Conditioner
85-135 VAC or 170-270 @ full load without using battery, to 70 VAC @ 75% load
85-135 VAC or 170-270 VAC
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input/output isolation:
     UPS
     Power Conditioner
2000 VA, up to 120 dB common mode, <5 mA leakage
1000 VA, up to 120 dB common mode, <5 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection:
     UPS
     Power Conditioner
Guarded 2 pole switch w/ (2) fuses, optional breaker
Guarded 2 pole switch w/ (2) fuses, optional breaker
Input power connection: Barrier terminal block, various options
INTERNAL BATTERY
Battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Battery life: Rated for continuous service life of 5 years
DC protection: Front panel mounted fuse standard, breaker optional
Battery expansion: Up to 24 hours w/ Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Two outputs standard, up to eight optional
Output control: Optional panel switches or breakers
Optional remote interlock ON/OFF control
Output receptacles: Barrier terminal block standard, various options
MECHANICAL
Dimensions ( H x D x W ): UPS 5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight: 105 lb. (48 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to front, others optional
Air intake filter: Washable filter media, others optional
ENVIRONMENTAL
Storage temperature: -13° to 140° F ambient (-25° to 60° C), lower/higher optional
Operating temperature: 32° to 113° F ambient (0° to 45° C ), lower/higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A standard
OPTIONAL ACCESSORIES
  Autoranging International Input, Cold Start, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface,  Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits