LinkedIn



ETI0001-2205A3 5.0 kVA

Part Number:
ETI0001-2205A3 
Rugged Mil Spec®5000 VA UPS
120 VAC Power Source with
3-Phase Input and 1-Phase Output
 


Rugged Mil Spec Rack Mount 5.0 kVA UPS
w/ 3-Phase Input, 1-Phase Output, Remote Battleshort,
and Remote Emergency Power Off
Intelligent SNMP/HTTP Interface


P/N:
ETI0001-2205A3 Rugged Mil Spec UPS Standard Front Panel Layout
with 3U and 2U Battery Shown in Rack Mount Configuration


P/N:
ETI0001-2205A3 Rugged Mil Spec UPS Standard Rear Panel Layout
with 3U and 2U Battery Shown in Rack Mount Configuration

The field proven Military Power® UPS line is ideally suited for military,industrial, computer and telecommunications applications requiring high reliability, ruggedconstruction, compact size and light weight design. These units are equallysuited for use in shipboard, airborne, vehicular, field deployed or fixedlocations with controlled or uncontrolled environments. The
ETI0001-2205A3 is being used as thepower source for Radar Systems because of the stringent performanceand reliability requirements. 

The heavy-duty UPS and Battery chasses have rounded metal corners and rugged handles frontand rear, aiding in safe handling. Internally, all major components are wellsecured and electrically insulated to prevent damage due to shock andvibration.  The internal intelligent thermal sensors provide monitoring of unit temperatures, with both local and remote Battleshort override capability of thermal shutdown for emergency scenarios. Battleshort can be engaged via a remote contact input or via a software command. When in Battleshort, an audible alarm is sounded and an indicator is lit. The high intensity audible alarm can be heard in high noise environments and includes an audible enable/disable switch. 

The internal shieldedinput transformer provides galvanic isolation with provisions for nominal 208 VAC, 3-phase inputvoltages. Special EMI/RFI filters and inputpower factor correction minimize both input current and harmonics. The inputcircuit breaker and the isolation transformerprovide an isolated source for all installations including shipboard systems oroverseas locations where phase references and grounding are not consistent. 50or 400 hertz outputs are available as an option. 

The unit can also operate as a frequency converter, taking 46-70 hertz input andconverting it to clean, uninterruptible 60 hertz power.

The LED arrays keep the operatorinformed as to the unit's status including load and battery levels. Thehigh intensity audible alarm can be heard in high noise environments. Allcontrols and protective devices are brought to the front and rear panels with criticalswitches having finger guards. The front panel also provides easy access to both the AC Input and Battery Input fuses. Coupled with the onboard spare fuses, MTTR is reduced to less than 15 minutes. Further, all front panel devices are recessed toprevent damage or accidental operation. Theinput circuit breaker and the galvanic isolation transformersall provide a double pole isolated source for all installations including shipboard systems oroverseas locations where phase references and grounding are not consistent.

The rear panel provides locking connectors for the inputand output power. Removable, washable air filters combined with high capacitystainless steel ball bearing fans provide added protection in both controlled and hostileenvironments. The exhaust air is diverted out the rear vents, withalternate air flow directions optional. The external battery connector allows the safe and easy addition ofthe standard or extra battery modules without having to shut the unit down.The batteries are maintenance free with immobilized electrolyte and areconstructed of flame retardant materials. For more information, see the BatteryTechnology section. TheStatus connector provides an interface with optional computer softwareproviding loss of AC and low battery status as well as remote shut downcapability.

See the Power Distribution Units section for alisting of stand alone PDUs. See the N5 Series section forversions of UPS with an integrated PDU and remote control.

Overall, the Military Power line is uniquely qualified for criticalshipboard, vehicle, airborne or land based systems combining advanced modular designfeatures with highly reliable construction.

Technical Specifications:
P/N:
ETI0001-2205A3

AC OUTPUT
Output voltage: 120 VAC true sinewave standard, up to 600 VAC optional
Output rating: UPS 5000 VA 0.8 pf standard
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 1.0% independent of input frequency
50, 400 or 1000 Hz output available as an option
Operational status AC Input status, UPS operational, UPS alarm, Battery level, Low battery, Load level, Overload, Warm temperature, Hot temperature, Fan fail and Battleshort LEDs,
Alarm contacts for Loss of AC and Low Battery
+90 dB audible alarm with audible on/off switch
SNMP/HTTP, Optional Asynchronous serial COM port
AC INPUT
Input voltage: Nominal 208 VAC L-L, 3-phase
Input voltage tolerance: UPS
148-234 VAC @ full load without using battery
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 99% typically
Input/output isolation: 6000 VA, up to 120 dB common mode, <1.0 mA leakage
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 3 pole 100 G shock rated circuit breaker (CB1)
plus UPS input fuses (F2A, F2B and F2C)
Input power connections: MS 3102R-24-22P, 4 pin, locking
EXTERNAL BATTERY
External battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
External battery life: Rated for continuous service life of 5 years
External DC protection: Front panel mounted fuses (F1A, F1B and F1C)
Battery expansion: Up to 24 hours w/ Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Two AC outputs standard
Output control: Circuit breakers (CB2 and CB3)
Remote ON/OFF of each load
Battleshort to inhibit shutdown when engaged
Remote Emergency Power Off (REPO)
Output receptacles: AC output MS3102R22-2 and MS3102R22-2SW 3-pin locking standard
MECHANICAL
Dimensions (H x D x W):
  UPS Module
  3U Battery Module
  2U Battery Module

8.75 (5U) x 23.5 x 19.0 in (222 x 597 x 483 mm)
5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm)
3.50 (2U) x 23.5 x 19.0 in (89 x 597 x 483 mm)
Rack Slide Mount Patterns: Jonathan, General Devices patterns, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight:
  UPS Module
  3U Battery/Bypass Module
  2U Battery Module

115 lb. (52 kg) UPS with lift handles front and rear
151 lb. (69 kg) Battery/Bypass with lift handles front and rear
100 lb. (45 kg) Battery with lift handles front and rear
Audible noise: Less than 59 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to front, others optional
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries
Operating temperature: -4° to 131° F ambient ( -20° to 55° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 45,000 ft (13,716 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810F, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; MIL STD 461E 
OPTIONAL ACCESSORIES
  Autoranging International Input, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits

Request Product Information
*(denotes required field)
Contact ETI by mail at:
Energy Technologies, Inc.
219 Park Avenue East
Mansfield, OH 44902-1845
USA

Contact ETI by phone or fax:
Voice: 419-522-4444
FAX: 419-522-4466